KiloVault® HAB™ 7.5 kWh Lithium Wall-Mount Energy Storage System

KiloVault® HAB™ Series Wall-Mount Energy Storage systems provide a 7.5 Kilowatt-hour battery in a single unit. Up to fourteen units can be used together for additional capacity. The HAB Series has been designed for trouble-free mounting and is easy to connect with other system components.

Features

  • Wall mounted
  • High safety LFP battery
  • Integrated Inverter Communications
  • Built-in WiFi for Performance Management 
  • Long cycle life (≥4000cycles)
  • High charge / discharge current
  • Intelligent LED & LCD display
  • Support for multi-battery modules in parallel

KiloVault HAB 7.5 Product Details

Description

High Safety LFP Battery
Non-toxic, thermally stable lithium iron phosphate (LFP) chemistry offers maximum safety and longevity. Cells are UL1642 certified.

Wall-Mounted Integrated Design
Sleek, wall-mounted design looks great with the rest of your power system.

Integrated Inverter Communication Support
Built-in Modbus provides digital communications with advanced inverters from Schneider and others.

Integrated WiFi for Management
Built-in WiFi allows connection to a local device or the HAB iT cloud performance monitoring network.

Long Cycle Life
After 4000 cycles at 80% Depth-of-Discharge the HAB will still have 80% of capacity left.

High Charge/ Discharge Current
Charge up to 120A (continuous) and discharge up to 150A (continuous) / 500A (peak 3 sec).

Intelligent LED & LCD Display
Easily view state of charge with the LED bar and access detailed performance and operating data on the built-in LCD display.

Expandable To 1.2 MWh/Month
Parallel up to 14 HABs to provide 3.3 Megawatt hours of storage per month.

Warranty
10 Year

 

Specifications

 

Rated Energy Capacity
(Watt Hours)
7500 Wh
DC Voltage Nominal 51.2V
Nominal Amp-Hour Capacity 150 Ah
Optimal Charger/Inverter Settings Bulk/Absorption: 56.4V recommended
Float: NA (2-stage-no-float for charging cycle)
Low Voltage Cut-Off: 48.0V
Equalization: Disable. Do not use.
(Battery will shut down into protection mode)
Maximum Cut-Off Voltage 59.0V
Minimum Cut-Off Voltage 48.0V
Max Charge Current 120A (Continuous)
Max Discharge Current 150A (Continuous)
Peak Discharge Current  (<3 secs) 500A
Operating Temperature Charging: 32 – 113°F (0 – 45°C)
Discharging: -4 – 140°F (-20 – 60°C)
Storage Temperature -4 to 110° F (-20° C to 45° C)
Cycle Life 4000 (80% DoD)
Battery Management System Monitors and optimizes charge & discharge for each battery in parallel and for each cell.   Provides overcharge, over discharge, temperature and short circuit protection for each battery.
Monitoring Wireless on-site detailed battery status monitoring (optional)
Self-Discharge Rate ≤ 2% per month
Maximum Configuration 14 batteries in parallel
Max Time Between Charges 6 months
Dimensions
(L X W X H)
8.79 in x 19.78 in x 25.09 in
Weight 207 lbs

Documents

 

Click to view or download the following product information and user manuals:

KiloVault HAB Data Sheet

KiloVault HAB Installation and User Manual Rev 1.13

KiloVault HAB 10 Year Warranty